IWILDT-150 Hunter Mobile Air Sampler
Introduction
IWILDT 150 Hunter high flow aerosol sampler with a sampling flow rate of 150m3/h. Mainly used for continuous sampling of outdoor aerosols. Glass fiber filter paper is used to collect aerosol particles, and activated carbon boxes are used to collect radioactive iodine.
characteristic
Durable: The shell and frame are made of stainless steel material, and the aluminum part has undergone anodizing treatment, with high-quality air pumps and electronic components.
High measurement accuracy: The special design of the air duct ensures minimal flow loss. The built-in processor calculates the air flow rate based on environmental conditions during sampling and adjusts the intake power in real time.
technical parameter
Working mode: capable of simultaneously collecting aerosols and iodine;
Aerosol sampling flow rate: 150m3/h;
Iodine sampling flow rate: 12m3/h;
Flow accuracy: ± 5%;
Filter paper area: 500cm2;
Sampling time: determined by the type of sampler, it can be used continuously for several days;
Siemens vacuum pump: with a service life of up to 25000 hours, it can withstand tropical climates;
Noise: less than 45dBA at 50m;
Power supply: 230V/50Hz, 1.5kW single-phase power or according to local standards.